You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
tdebase/twin/wm-spec/x340.html

182 lines
3.0 KiB

<HTML
><HEAD
><TITLE
>Window Manager Protocols</TITLE
><META
NAME="GENERATOR"
CONTENT="Modular DocBook HTML Stylesheet Version 1.72
"><LINK
REL="HOME"
HREF="index.html"><LINK
REL="PREVIOUS"
TITLE="Application Window Properties"
HREF="x225.html"><LINK
REL="NEXT"
TITLE="Implementation notes"
HREF="x351.html"></HEAD
><BODY
CLASS="SECT1"
BGCOLOR="#FFFFFF"
TEXT="#000000"
LINK="#0000FF"
VLINK="#840084"
ALINK="#0000FF"
><DIV
CLASS="NAVHEADER"
><TABLE
SUMMARY="Header navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TH
COLSPAN="3"
ALIGN="center"
></TH
></TR
><TR
><TD
WIDTH="10%"
ALIGN="left"
VALIGN="bottom"
><A
HREF="x225.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="80%"
ALIGN="center"
VALIGN="bottom"
></TD
><TD
WIDTH="10%"
ALIGN="right"
VALIGN="bottom"
><A
HREF="x351.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
></TABLE
><HR
ALIGN="LEFT"
WIDTH="100%"></DIV
><DIV
CLASS="SECT1"
><H1
CLASS="SECT1"
><A
NAME="AEN340"
>6. Window Manager Protocols</A
></H1
><DIV
CLASS="SECT2"
><H2
CLASS="SECT2"
><A
NAME="AEN342"
>6.1. _NET_WM_PING</A
></H2
><P
>This protocol allows the Window Manager to determine if the Client is still
processing X events. This can be used by the Window Manager to determine if a
window which fails to close after being sent WM_DELETE_WINDOW has stopped
responding, or has stalled for some other reason, such as waiting for user
confirmation. A Client SHOULD indicate that it is willing to participate in
this protocol by listing _NET_WM_PING in the WM_PROTOCOLS property of the
client window.
</P
><P
>A Window Manager can use this protocol at any time by sending a client message
as follows:
</P
><PRE
CLASS="PROGRAMLISTING"
>type = ClientMessage
window = the respective client window
message_type = WM_PROTOCOLS
format = 32
data.l[0] = _NET_WM_PING
data.l[1] = timestamp</PRE
><P
>A participating Client receiving this message MUST send it back to the root
window immediately, by setting window = root, and calling XSendEvent. The
Client MUST NOT alter the timestamp, as this can be used by the Window Manager
to uniquely identify the ping.
</P
><P
>The Window Manager MAY kill the Client (using _NET_WM_PID) if it fails to
respond to this protocol within a reasonable time.
</P
><P
>See also the implementation notes on <A
HREF="x351.html#KILLINGWINDOWS"
>killing hung processes</A
>.
</P
></DIV
></DIV
><DIV
CLASS="NAVFOOTER"
><HR
ALIGN="LEFT"
WIDTH="100%"><TABLE
SUMMARY="Footer navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
><A
HREF="x225.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="index.html"
ACCESSKEY="H"
>Home</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
><A
HREF="x351.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
>Application Window Properties</TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
>&nbsp;</TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
>Implementation notes</TD
></TR
></TABLE
></DIV
></BODY
></HTML
>