@ -3082,11 +3082,16 @@ void TDEHardwareDevices::updateExistingDeviceInformation(TDEGenericDevice* exist
}
// Calculate time remaining
// Discharge rate is in watt-hours
// Discharge/charge rate is in watt-hours
// Energy is in watt-hours
// Therefore, energy/rate = time in hours
// Convert to seconds...
bdevice->internalSetTimeRemaining((bdevice->energy()/bdevice->dischargeRate())*60*60);
if (bdevice->status() == TDEBatteryStatus::Charging) {
bdevice->internalSetTimeRemaining(((bdevice->maximumEnergy()-bdevice->energy())/bdevice->dischargeRate())*60*60);
}
else {
bdevice->internalSetTimeRemaining((bdevice->energy()/bdevice->dischargeRate())*60*60);
}
}
if (device->type() == TDEGenericDeviceType::PowerSupply) {